Updated clinical guidelines experience major reporting limitations

ABSTARCT: The Checklist for the Reporting of Updated Guidelines (CheckUp) was recently developed. However, so far, no systematic assessment of the reporting of updated clinical guidelines (CGs) exists. We aimed to examine (1) the completeness of reporting the updating process in CGs and (2) the inte...

Full description

Autores:
Martínez García, Laura Beatriz
Flórez Gómez, Iván Darío
Hidalgo Armas, Laura
Brouwers, Melissa
Vernooij, Robin W.M.
Coello, Pablo Alonso
Poorthuis, Michiel H.F.
Tipo de recurso:
Article of investigation
Fecha de publicación:
2017
Institución:
Universidad de Antioquia
Repositorio:
Repositorio UdeA
Idioma:
eng
OAI Identifier:
oai:bibliotecadigital.udea.edu.co:10495/9125
Acceso en línea:
http://hdl.handle.net/10495/9125
Palabra clave:
Professional standars review organizations (Medicine)
Organizaciones para la revisión de normas profesionales (Medicina)
Standards
Health facilities
Instituciones de salud
Rights
openAccess
License
http://creativecommons.org/licenses/by/2.5/co/
id UDEA2_8b72d829f75fdcfc5cbdf9c816d1ad29
oai_identifier_str oai:bibliotecadigital.udea.edu.co:10495/9125
network_acronym_str UDEA2
network_name_str Repositorio UdeA
repository_id_str
dc.title.spa.fl_str_mv Updated clinical guidelines experience major reporting limitations
title Updated clinical guidelines experience major reporting limitations
spellingShingle Updated clinical guidelines experience major reporting limitations
Professional standars review organizations (Medicine)
Organizaciones para la revisión de normas profesionales (Medicina)
Standards
Health facilities
Instituciones de salud
title_short Updated clinical guidelines experience major reporting limitations
title_full Updated clinical guidelines experience major reporting limitations
title_fullStr Updated clinical guidelines experience major reporting limitations
title_full_unstemmed Updated clinical guidelines experience major reporting limitations
title_sort Updated clinical guidelines experience major reporting limitations
dc.creator.fl_str_mv Martínez García, Laura Beatriz
Flórez Gómez, Iván Darío
Hidalgo Armas, Laura
Brouwers, Melissa
Vernooij, Robin W.M.
Coello, Pablo Alonso
Poorthuis, Michiel H.F.
dc.contributor.author.none.fl_str_mv Martínez García, Laura Beatriz
Flórez Gómez, Iván Darío
Hidalgo Armas, Laura
Brouwers, Melissa
Vernooij, Robin W.M.
Coello, Pablo Alonso
Poorthuis, Michiel H.F.
dc.contributor.researchgroup.spa.fl_str_mv Grupo de Investigación Clínica en Enfermedades del Niño y del Adolescente - Pediaciencias
dc.subject.none.fl_str_mv Professional standars review organizations (Medicine)
Organizaciones para la revisión de normas profesionales (Medicina)
Standards
Health facilities
Instituciones de salud
topic Professional standars review organizations (Medicine)
Organizaciones para la revisión de normas profesionales (Medicina)
Standards
Health facilities
Instituciones de salud
description ABSTARCT: The Checklist for the Reporting of Updated Guidelines (CheckUp) was recently developed. However, so far, no systematic assessment of the reporting of updated clinical guidelines (CGs) exists. We aimed to examine (1) the completeness of reporting the updating process in CGs and (2) the inter-observer reliability of CheckUp. METHODS: We conducted a systematic assessment of the reporting of the updating process in a sample of updated CGs using CheckUp. We performed a systematic search to identify updated CGs published in 2015, developed by a professional society, reporting a systematic review of the evidence, and containing at least one recommendation. Three reviewers independently assessed the CGs with CheckUp (16 items). We calculated the median score per item, per domain, and overall, converting scores to a 10-point scale. Multiple linear regression analyses were used to identify differences according to country, type of organisation, scope, and health topic of updated CGs. We calculated the intraclass coefficient (ICC) and 95% confidence interval (95% CI) for domains and overall score. RESULTS: We included in total 60 updated CGs. The median domain score on a 10-point scale for presentation was 5.8 (range 1.7 to 10), for editorial independence 8.3 (range 3.3 to 10), and for methodology 5.7 (range 0 to 10). The median overall score on a 10-point scale was 6.3 (range 3.1 to 10). Presentation and justification items at recommendation level (respectively reported by 27 and 38% of the CGs) and the methods used for the external review and implementing changes in practice were particularly poorly reported (both reported by 38% of the CGs). CGs developed by a European or international institution obtained a statistically significant higher overall score compared to North American or Asian institutions (p = 0.014). Finally, the agreement among the reviewers on the overall score was excellent (ICC 0.88, 95% CI 0.75 to 0.95). CONCLUSIONS: The reporting of updated CGs varies considerably with significant room for improvement. We recommend using CheckUp to assess the updating process in updated CGs and as a blueprint to inform methods and reporting strategies in updating."
publishDate 2017
dc.date.issued.none.fl_str_mv 2017
dc.date.accessioned.none.fl_str_mv 2018-02-28T18:49:11Z
dc.date.available.none.fl_str_mv 2018-02-28T18:49:11Z
dc.type.spa.fl_str_mv Artículo de investigación
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.redcol.spa.fl_str_mv https://purl.org/redcol/resource_type/ART
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
format http://purl.org/coar/resource_type/c_2df8fbb1
status_str publishedVersion
dc.identifier.citation.spa.fl_str_mv Vernooij RWM, Martínez García L, Florez ID, Hildago Armas L, Poorthuis MHF, Brouwers M, Alonso-Coello P. Updated clinical guidelines experience major reporting limitations. Implement Sci. 2017;12(120):1-10 DOI: 10.1186/s13012-017-0651-3.
dc.identifier.issn.none.fl_str_mv 1748-5908
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10495/9125
dc.identifier.doi.none.fl_str_mv 10.1186/s13012-017-0651-3
identifier_str_mv Vernooij RWM, Martínez García L, Florez ID, Hildago Armas L, Poorthuis MHF, Brouwers M, Alonso-Coello P. Updated clinical guidelines experience major reporting limitations. Implement Sci. 2017;12(120):1-10 DOI: 10.1186/s13012-017-0651-3.
1748-5908
10.1186/s13012-017-0651-3
url http://hdl.handle.net/10495/9125
dc.language.iso.spa.fl_str_mv eng
language eng
dc.relation.ispartofjournalabbrev.spa.fl_str_mv Implement. Sci.
dc.relation.citationendpage.spa.fl_str_mv 1-10
dc.relation.citationissue.spa.fl_str_mv 1
dc.relation.citationstartpage.spa.fl_str_mv 1
dc.relation.citationvolume.spa.fl_str_mv 12
dc.relation.ispartofjournal.spa.fl_str_mv Implementation science
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by/2.5/co/
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by/4.0/
dc.rights.accessrights.*.fl_str_mv Atribución 2.5
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv http://creativecommons.org/licenses/by/2.5/co/
https://creativecommons.org/licenses/by/4.0/
Atribución 2.5
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.extent.spa.fl_str_mv 10
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.place.spa.fl_str_mv Reino Unido
Londres, Inglaterra
institution Universidad de Antioquia
bitstream.url.fl_str_mv https://bibliotecadigital.udea.edu.co/bitstreams/9b90a160-1e2e-4309-ac20-7c2577771b8c/download
https://bibliotecadigital.udea.edu.co/bitstreams/48b12525-4a57-4e9e-9a80-78b21b105751/download
https://bibliotecadigital.udea.edu.co/bitstreams/fa83541e-4729-4be0-9675-386b622268e1/download
https://bibliotecadigital.udea.edu.co/bitstreams/199f4a6b-f02e-4f2c-ab6c-e722e4bb3a8a/download
https://bibliotecadigital.udea.edu.co/bitstreams/1386cd89-4247-47a3-b887-a7df1265478e/download
https://bibliotecadigital.udea.edu.co/bitstreams/be0694d9-741b-4b86-999a-ad256f6de788/download
https://bibliotecadigital.udea.edu.co/bitstreams/f5643ac9-9460-46a2-bedd-adf2208065e0/download
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
4afdbb8c545fd630ea7db775da747b2f
d41d8cd98f00b204e9800998ecf8427e
d41d8cd98f00b204e9800998ecf8427e
76b6fda491be0a948a4ad039d2125e00
3bffa671df4769dab20cd5d953f6a8e5
c58bed48a22ad6d4fccf40ba2c056d2f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional de la Universidad de Antioquia
repository.mail.fl_str_mv aplicacionbibliotecadigitalbiblioteca@udea.edu.co
_version_ 1851052584430731264
spelling Martínez García, Laura BeatrizFlórez Gómez, Iván DaríoHidalgo Armas, LauraBrouwers, MelissaVernooij, Robin W.M.Coello, Pablo AlonsoPoorthuis, Michiel H.F.Grupo de Investigación Clínica en Enfermedades del Niño y del Adolescente - Pediaciencias2018-02-28T18:49:11Z2018-02-28T18:49:11Z2017Vernooij RWM, Martínez García L, Florez ID, Hildago Armas L, Poorthuis MHF, Brouwers M, Alonso-Coello P. Updated clinical guidelines experience major reporting limitations. Implement Sci. 2017;12(120):1-10 DOI: 10.1186/s13012-017-0651-3.1748-5908http://hdl.handle.net/10495/912510.1186/s13012-017-0651-3ABSTARCT: The Checklist for the Reporting of Updated Guidelines (CheckUp) was recently developed. However, so far, no systematic assessment of the reporting of updated clinical guidelines (CGs) exists. We aimed to examine (1) the completeness of reporting the updating process in CGs and (2) the inter-observer reliability of CheckUp. METHODS: We conducted a systematic assessment of the reporting of the updating process in a sample of updated CGs using CheckUp. We performed a systematic search to identify updated CGs published in 2015, developed by a professional society, reporting a systematic review of the evidence, and containing at least one recommendation. Three reviewers independently assessed the CGs with CheckUp (16 items). We calculated the median score per item, per domain, and overall, converting scores to a 10-point scale. Multiple linear regression analyses were used to identify differences according to country, type of organisation, scope, and health topic of updated CGs. We calculated the intraclass coefficient (ICC) and 95% confidence interval (95% CI) for domains and overall score. RESULTS: We included in total 60 updated CGs. The median domain score on a 10-point scale for presentation was 5.8 (range 1.7 to 10), for editorial independence 8.3 (range 3.3 to 10), and for methodology 5.7 (range 0 to 10). The median overall score on a 10-point scale was 6.3 (range 3.1 to 10). Presentation and justification items at recommendation level (respectively reported by 27 and 38% of the CGs) and the methods used for the external review and implementing changes in practice were particularly poorly reported (both reported by 38% of the CGs). CGs developed by a European or international institution obtained a statistically significant higher overall score compared to North American or Asian institutions (p = 0.014). Finally, the agreement among the reviewers on the overall score was excellent (ICC 0.88, 95% CI 0.75 to 0.95). CONCLUSIONS: The reporting of updated CGs varies considerably with significant room for improvement. We recommend using CheckUp to assess the updating process in updated CGs and as a blueprint to inform methods and reporting strategies in updating."COL005878410application/pdfenghttp://creativecommons.org/licenses/by/2.5/co/https://creativecommons.org/licenses/by/4.0/Atribución 2.5info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Professional standars review organizations (Medicine)Organizaciones para la revisión de normas profesionales (Medicina)StandardsHealth facilitiesInstituciones de saludUpdated clinical guidelines experience major reporting limitationsArtículo de investigaciónhttp://purl.org/coar/resource_type/c_2df8fbb1https://purl.org/redcol/resource_type/ARThttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionReino UnidoLondres, InglaterraImplement. Sci.1-101112Implementation sciencePublicationLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://bibliotecadigital.udea.edu.co/bitstreams/9b90a160-1e2e-4309-ac20-7c2577771b8c/download8a4605be74aa9ea9d79846c1fba20a33MD55falseAnonymousREADCC-LICENSElicense_urllicense_urltext/plain; charset=utf-849https://bibliotecadigital.udea.edu.co/bitstreams/48b12525-4a57-4e9e-9a80-78b21b105751/download4afdbb8c545fd630ea7db775da747b2fMD52falseAnonymousREADlicense_textlicense_texttext/html; charset=utf-80https://bibliotecadigital.udea.edu.co/bitstreams/fa83541e-4729-4be0-9675-386b622268e1/downloadd41d8cd98f00b204e9800998ecf8427eMD53falseAnonymousREADlicense_rdflicense_rdfapplication/rdf+xml; charset=utf-80https://bibliotecadigital.udea.edu.co/bitstreams/199f4a6b-f02e-4f2c-ab6c-e722e4bb3a8a/downloadd41d8cd98f00b204e9800998ecf8427eMD54falseAnonymousREADORIGINALVernooijRobin_2017_UpdatedClinicalGuidelines.pdfVernooijRobin_2017_UpdatedClinicalGuidelines.pdfArtículo de investigaciónapplication/pdf1149640https://bibliotecadigital.udea.edu.co/bitstreams/1386cd89-4247-47a3-b887-a7df1265478e/download76b6fda491be0a948a4ad039d2125e00MD51trueAnonymousREADTEXTVernooijRobin_2017_UpdatedClinicalGuidelines.pdf.txtVernooijRobin_2017_UpdatedClinicalGuidelines.pdf.txtExtracted texttext/plain49811https://bibliotecadigital.udea.edu.co/bitstreams/be0694d9-741b-4b86-999a-ad256f6de788/download3bffa671df4769dab20cd5d953f6a8e5MD56falseAnonymousREADTHUMBNAILVernooijRobin_2017_UpdatedClinicalGuidelines.pdf.jpgVernooijRobin_2017_UpdatedClinicalGuidelines.pdf.jpgGenerated Thumbnailimage/jpeg14295https://bibliotecadigital.udea.edu.co/bitstreams/f5643ac9-9460-46a2-bedd-adf2208065e0/downloadc58bed48a22ad6d4fccf40ba2c056d2fMD57falseAnonymousREAD10495/9125oai:bibliotecadigital.udea.edu.co:10495/91252025-03-27 00:39:25.249http://creativecommons.org/licenses/by/2.5/co/open.accesshttps://bibliotecadigital.udea.edu.coRepositorio Institucional de la Universidad de Antioquiaaplicacionbibliotecadigitalbiblioteca@udea.edu.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