Efficiency of the removal of microcystin-LR byUV-radiation and hydrogen peroxide

ABSTRACT : Due to the harmful effects associated with the presence of microcystin-LR (MC-LR) cyanotoxin, photo-degradation assays were performed in natural and distilled water using the combined action of ultraviolet (UV) radiation and hydrogen peroxide (H2O2). The effect of H2O2 content and UV irra...

Full description

Autores:
Loaiza González, Jinna Marcela
León Salazar, Melba Cristina
Rubio Clemente, Ainhoa
Rodriguez Loaiza, Diana Catalina
Peñuela Mesa, Gustavo Antonio
Tipo de recurso:
Article of investigation
Fecha de publicación:
2020
Institución:
Universidad de Antioquia
Repositorio:
Repositorio UdeA
Idioma:
eng
OAI Identifier:
oai:bibliotecadigital.udea.edu.co:10495/24956
Acceso en línea:
http://hdl.handle.net/10495/24956
Palabra clave:
Polución del agua
Water pollution
Toxinas
Toxins
Tratamiento del agua
Water treatment
Procesos de oxidación avanzada
http://aims.fao.org/aos/agrovoc/c_8321
http://aims.fao.org/aos/agrovoc/c_7828
http://aims.fao.org/aos/agrovoc/c_ef195799
Rights
openAccess
License
https://creativecommons.org/licenses/by-nc-sa/4.0/
Description
Summary:ABSTRACT : Due to the harmful effects associated with the presence of microcystin-LR (MC-LR) cyanotoxin, photo-degradation assays were performed in natural and distilled water using the combined action of ultraviolet (UV) radiation and hydrogen peroxide (H2O2). The effect of H2O2 content and UV irradiance was evaluated and optimized using a multilevel factorial design in distilled water spiked with 20 µg L-1 MC-LR. The coupled UV/H2O2 system under optimal operating conditions (0.63 mW cm-2 irradiance and 30 mg L-1 H2O2) was more effective than the individual action of UV irradiance or H2O2 content for 30 min of treatment time, since a reduction of 97.78% of MC-LR was achieved. After optimizing the operating conditions, they were applied for natural water, obtaining MC-LR removals similar to those achieved with distilled water (99.59 and 99.73%, respectively), reaching a final MC-LR concentration in both matrices well below the maximum recommended limit established by WHO for MC-LR in drinking water, fixed at 1 µg L-1. 15 mg L-1 of H2O2 were also tested, and although 98.08% of MC-LR elimination was found for a reaction time of 60 min, WHO advisable limit was not surpassed. The UV/H2O2 process could be considered as an alternative to the conventional processes water facilities are operating with to tackle the problem of fresh water pollution with cyanotoxins, providing the accomplishment of the whole set of water quality standards included in the legislation.