Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009

Propia

Autores:
Rangel Castro, Carlos Andrés
Tipo de recurso:
Trabajo de grado de pregrado
Fecha de publicación:
2024
Institución:
Universidad Antonio Nariño
Repositorio:
Repositorio UAN
Idioma:
spa
OAI Identifier:
oai:repositorio.uan.edu.co:123456789/12624
Acceso en línea:
https://repositorio.uan.edu.co/handle/123456789/12624
Palabra clave:
Básculas
Calibración
Confiabilidad Metrológica
Proceso de Combustión
Trazabilidad
Scales
Calibration
Metrological Reliability
Combustion Process
Traceability
Rights
openAccess
License
Attribution-NonCommercial-NoDerivs 2.5 Colombia
id UAntonioN2_d07f5c9fd2aef6eabacc80132dc4c67c
oai_identifier_str oai:repositorio.uan.edu.co:123456789/12624
network_acronym_str UAntonioN2
network_name_str Repositorio UAN
repository_id_str
dc.title.none.fl_str_mv Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
title Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
spellingShingle Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
Básculas
Calibración
Confiabilidad Metrológica
Proceso de Combustión
Trazabilidad
Scales
Calibration
Metrological Reliability
Combustion Process
Traceability
title_short Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
title_full Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
title_fullStr Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
title_full_unstemmed Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
title_sort Evaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009
dc.creator.fl_str_mv Rangel Castro, Carlos Andrés
dc.contributor.advisor.none.fl_str_mv Hernández Vásquez, José Daniel
dc.contributor.author.none.fl_str_mv Rangel Castro, Carlos Andrés
dc.subject.none.fl_str_mv Básculas
Calibración
Confiabilidad Metrológica
Proceso de Combustión
Trazabilidad
topic Básculas
Calibración
Confiabilidad Metrológica
Proceso de Combustión
Trazabilidad
Scales
Calibration
Metrological Reliability
Combustion Process
Traceability
dc.subject.keyword.none.fl_str_mv Scales
Calibration
Metrological Reliability
Combustion Process
Traceability
description Propia
publishDate 2024
dc.date.created.none.fl_str_mv 2024-12-02
dc.date.accessioned.none.fl_str_mv 2025-04-10T23:40:17Z
dc.date.available.none.fl_str_mv 2025-04-10T23:40:17Z
dc.date.issued.none.fl_str_mv 2025-04-10
dc.type.none.fl_str_mv Tesis/Trabajo de grado - Monografía - Pregrado
dc.type.document.none.fl_str_mv Estudio descriptivo
dc.type.version.none.fl_str_mv info:eu-repo/semantics/acceptedVersion
dc.type.coar.none.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.redcol.none.fl_str_mv http://purl.org/redcol/resource_type/PID
format http://purl.org/coar/resource_type/c_7a1f
status_str acceptedVersion
dc.identifier.uri.none.fl_str_mv https://repositorio.uan.edu.co/handle/123456789/12624
url https://repositorio.uan.edu.co/handle/123456789/12624
dc.language.iso.fl_str_mv spa
language spa
dc.rights.en.fl_str_mv Attribution-NonCommercial-NoDerivs 2.5 Colombia
dc.rights.uri.none.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rights.accessrights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Attribution-NonCommercial-NoDerivs 2.5 Colombia
http://creativecommons.org/licenses/by-nc-nd/2.5/co/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.medium.none.fl_str_mv Pdf
dc.publisher.none.fl_str_mv Universidad Antonio Nariño
dc.publisher.program.none.fl_str_mv Ingeniería Mecánica
dc.publisher.faculty.none.fl_str_mv Facultad de Ingeniería Mecánica, Electrónica y Biomédica
dc.publisher.campus.none.fl_str_mv Puerto Colombia Barranquilla
publisher.none.fl_str_mv Universidad Antonio Nariño
dc.source.none.fl_str_mv instname:Universidad Antonio Nariño
instname_str Universidad Antonio Nariño
institution Universidad Antonio Nariño
dc.source.bibliographicCitation.none.fl_str_mv S. I. D. METROLOGIA, "Guía para la calibración de los instrumentos para pesar de funcionamiento no automático," ed, 2009.
Recommendation, "R 76-1: Nonautomatic weighing instruments, Part 1: Metro logical and technical requirements–Tests," OIML, Paris, 2006.
IS010012, "Measurement management systems Requirements for measurement processes and measuring equipment," ed: 2003, 2003
] Standard, "ENVIRONMENTAL MANAGEMENT SYSTEMS—REQUIREMENTS WITH GUIDANCE FOR USE," DS/EN ISO, vol. 14001, 2004.
ISO, "ISO/IEC17025: 2005 General Requirements for the Competence of Testing and Calibration Laboratories," Switzerland: ISO, 2005.
Standardization, ISO 9001: 2008: Quality Management Systems-Requirements: International Organization for Standardization, 2000.
Becerra, L. Control Estadístico de las Mediciones. 2008.
Tapias, J. Evaluación de la confiabilidad metrológica de los instrumentos no automáticos de pesaje en los laboratorios de la universidad del atlántico. Barranquilla. 2017.
GUM, I. Guide to the Expression of Uncertainty in Measurement, with Supplement 1, Evaluation of measurement data, JCGM 101. Organization for Standardization, Geneva, Switzerland. 2008
Senar, J. La Medición de la Repetibilidad y el error de Medida, Temas Actuales en Etología. 17(1), 53-64. 1999.
bitstream.url.fl_str_mv https://repositorio.uan.edu.co/bitstreams/d4a3640f-7cb2-474e-91d9-45d803c281d3/download
https://repositorio.uan.edu.co/bitstreams/4470eadc-7872-4eae-8c27-4e825279a33f/download
https://repositorio.uan.edu.co/bitstreams/372cae7c-f016-43fb-a4a9-3e586b993e77/download
https://repositorio.uan.edu.co/bitstreams/deda50e8-adf9-4956-b69f-da8c7afd65e7/download
bitstream.checksum.fl_str_mv 783c536cdf22e38d4d9a908ce798f2b9
60e7eecbfa83fd759c2e1b7bef4166a4
0e7176b762aa11f4c059eb73689cba21
217700a34da79ed616c2feb68d4c5e06
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional UAN
repository.mail.fl_str_mv alertas.repositorio@uan.edu.co
_version_ 1851059405777272832
spelling Hernández Vásquez, José DanielRangel Castro, Carlos Andrés2025-04-10T23:40:17Z2025-04-10T23:40:17Z2024-12-022025-04-10https://repositorio.uan.edu.co/handle/123456789/12624PropiaThis project had as its main objective to carry out a metrological evaluation of a scale used in an engine laboratory, applying the methods established in the SIM 2009 Guide. The relevance of this study lay in ensuring the accuracy and reliability of the measurements made with the equipment, since these are essential to properly assess engine performance. The methodology implemented included several key steps. Firstly, the calibration of the scale was verified by using reference patterns traceable to national standards, thus ensuring the validity of the results. Subsequently, systematic tests were carried out to assess its accuracy and precision under controlled conditions. Finally, the uncertainty associated with the measurements was analysed, allowing a detailed understanding of the metrological performance of the equipment to be obtained. The results obtained pointed out specific areas where the scale's performance could be improved. This work not only contributed significantly to improving the quality of measurements made in the engine laboratory, but also established a solid methodological framework for future metrological evaluations of similar equipment in industrial environments. As a contribution, this study highlighted the importance of metrology as a key factor in the accuracy of technical measurements and quality control in industrial processes related to engine performance analysis.UAN Proyectos de ciencia, tecnología, innovación y creación artísticaEste proyecto tuvo como objetivo principal realizar una evaluación metrológica de una báscula utilizada en un laboratorio de motores, aplicando los métodos establecidos en la Guía SIM 2009. La relevancia de este estudio residió en garantizar la precisión y confiabilidad de las mediciones realizadas con el equipo, dado que estas son esenciales para evaluar de manera adecuada el rendimiento de los motores. La metodología implementada incluyó varios pasos clave. En primer lugar, se verificó la calibración de la báscula mediante el uso de patrones de referencia trazables a estándares nacionales, asegurando así la validez de los resultados. Posteriormente, se llevaron a cabo ensayos sistemáticos para evaluar su exactitud y precisión en condiciones controladas. Finalmente, se analizó la incertidumbre asociada a las mediciones, lo que permitió obtener una comprensión detallada del desempeño metrológico del equipo. Los resultados obtenidos señalaron áreas específicas en las que el rendimiento de la báscula podría mejorarse. Este trabajo no solo contribuyó significativamente a la mejora de la calidad de las mediciones realizadas en el laboratorio de motores, sino que también estableció un marco metodológico sólido para futuras evaluaciones metrológicas de equipos similares en entornos industriales. Como contribución, este estudio resaltó la importancia de la metrología como un factor clave en la precisión de las mediciones técnicas y el control de calidad en procesos industriales relacionados con el análisis del rendimiento de motores.FinalIngeniero(a) Mecánico(a)PregradoPresencialProyectoPdfUniversidad Antonio NariñoIngeniería MecánicaFacultad de Ingeniería Mecánica, Electrónica y BiomédicaPuerto Colombia BarranquillaAttribution-NonCommercial-NoDerivs 2.5 Colombiahttp://creativecommons.org/licenses/by-nc-nd/2.5/co/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2instname:Universidad Antonio NariñoS. I. D. METROLOGIA, "Guía para la calibración de los instrumentos para pesar de funcionamiento no automático," ed, 2009.Recommendation, "R 76-1: Nonautomatic weighing instruments, Part 1: Metro logical and technical requirements–Tests," OIML, Paris, 2006.IS010012, "Measurement management systems Requirements for measurement processes and measuring equipment," ed: 2003, 2003] Standard, "ENVIRONMENTAL MANAGEMENT SYSTEMS—REQUIREMENTS WITH GUIDANCE FOR USE," DS/EN ISO, vol. 14001, 2004.ISO, "ISO/IEC17025: 2005 General Requirements for the Competence of Testing and Calibration Laboratories," Switzerland: ISO, 2005.Standardization, ISO 9001: 2008: Quality Management Systems-Requirements: International Organization for Standardization, 2000.Becerra, L. Control Estadístico de las Mediciones. 2008.Tapias, J. Evaluación de la confiabilidad metrológica de los instrumentos no automáticos de pesaje en los laboratorios de la universidad del atlántico. Barranquilla. 2017.GUM, I. Guide to the Expression of Uncertainty in Measurement, with Supplement 1, Evaluation of measurement data, JCGM 101. Organization for Standardization, Geneva, Switzerland. 2008Senar, J. La Medición de la Repetibilidad y el error de Medida, Temas Actuales en Etología. 17(1), 53-64. 1999.BásculasCalibraciónConfiabilidad MetrológicaProceso de CombustiónTrazabilidadScalesCalibrationMetrological ReliabilityCombustion ProcessTraceabilityEvaluación Metrológica De Una Báscula Utilizada En Un Laboratorio De Motores Utilizando Los Métodos De La Guía SIM 2009Tesis/Trabajo de grado - Monografía - PregradoEstudio descriptivoinfo:eu-repo/semantics/acceptedVersionhttp://purl.org/coar/resource_type/c_7a1fhttp://purl.org/redcol/resource_type/PIDEspecializadaspaORIGINAL2024_RangelCastroCarlosAndres2024_RangelCastroCarlosAndresTrabajo De Gradoapplication/pdf1194679https://repositorio.uan.edu.co/bitstreams/d4a3640f-7cb2-474e-91d9-45d803c281d3/download783c536cdf22e38d4d9a908ce798f2b9MD512024_RangelCastroCarlosAndres_Autorizacion2024_RangelCastroCarlosAndres_AutorizacionAutorizaciónapplication/pdf1268118https://repositorio.uan.edu.co/bitstreams/4470eadc-7872-4eae-8c27-4e825279a33f/download60e7eecbfa83fd759c2e1b7bef4166a4MD532024_RangelCastroCarlosAndres_Acta2024_RangelCastroCarlosAndres_ActaActaapplication/pdf162928https://repositorio.uan.edu.co/bitstreams/372cae7c-f016-43fb-a4a9-3e586b993e77/download0e7176b762aa11f4c059eb73689cba21MD54CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.uan.edu.co/bitstreams/deda50e8-adf9-4956-b69f-da8c7afd65e7/download217700a34da79ed616c2feb68d4c5e06MD52123456789/12624oai:repositorio.uan.edu.co:123456789/126242025-04-10 23:40:20.305http://creativecommons.org/licenses/by-nc-nd/2.5/co/Attribution-NonCommercial-NoDerivs 2.5 Colombiaopen.accesshttps://repositorio.uan.edu.coRepositorio Institucional UANalertas.repositorio@uan.edu.co