Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator

In the present work of degree, it is presented the implementation of a system of wastewater treatment, through the technology of activated sludge to the domestic wastewater generated in the institutional activities of the San Viator school for its later dumping in the wetland of Torca -Guaymaral, si...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2017
Institución:
Universidad de América
Repositorio:
Lumieres
Idioma:
spa
OAI Identifier:
oai:repository.uamerica.edu.co:20.500.11839/6578
Acceso en línea:
https://hdl.handle.net/20.500.11839/6578
Palabra clave:
Lodos activados
Reactor aerobio
Crecimiento biológico
Activated sludge
Aerobic reactor
Biological growth
Tesis y disertaciones académicas
Rights
License
Atribución – No comercial
id Lumieres_50270b1cef273eff020c83ae6f85df4f
oai_identifier_str oai:repository.uamerica.edu.co:20.500.11839/6578
network_acronym_str Lumieres
network_name_str Lumieres
repository_id_str
dc.title.none.fl_str_mv Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
title Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
spellingShingle Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
Lodos activados
Reactor aerobio
Crecimiento biológico
Activated sludge
Aerobic reactor
Biological growth
Tesis y disertaciones académicas
title_short Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
title_full Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
title_fullStr Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
title_full_unstemmed Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
title_sort Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator
dc.contributor.none.fl_str_mv Osorio, Gilberto Andrés
dc.subject.none.fl_str_mv Lodos activados
Reactor aerobio
Crecimiento biológico
Activated sludge
Aerobic reactor
Biological growth
Tesis y disertaciones académicas
topic Lodos activados
Reactor aerobio
Crecimiento biológico
Activated sludge
Aerobic reactor
Biological growth
Tesis y disertaciones académicas
description In the present work of degree, it is presented the implementation of a system of wastewater treatment, through the technology of activated sludge to the domestic wastewater generated in the institutional activities of the San Viator school for its later dumping in the wetland of Torca -Guaymaral, since the preliminary treatment that is currently carried out does not meet the requirements of environmental regulations. For the evaluation of this treatment, the project was divided into three phases, firstly, the diagnosis and characterization of the wastewater sources, finding that parameters such as total suspended solids, fats and oils, COD and BOD5 do not comply with the Provisions. Subsequently, the treatment alternative chosen by means of the construction, commissioning and operation of a conventional system of activated sludge on a laboratory scale is developed experimentally, allowing the determination of the biological growth kinetic coefficients used in the third phase of the project, which corresponds to the dimensioning Of the units involved in the treatment system. Finally, and based on quotations, the costs of the installation and proper operation of an activated sludge treatment train are estimated.
publishDate 2017
dc.date.none.fl_str_mv 2017-08-23
2018-07-05T17:55:32Z
2018-07-05T17:55:32Z
dc.type.none.fl_str_mv bachelorThesis
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.identifier.none.fl_str_mv APA 6th - Ramos Velandia, C. C. (2017) Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6578
https://hdl.handle.net/20.500.11839/6578
identifier_str_mv APA 6th - Ramos Velandia, C. C. (2017) Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6578
url https://hdl.handle.net/20.500.11839/6578
dc.language.iso.fl_str_mv spa
language spa
dc.rights.none.fl_str_mv Atribución – No comercial
http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Atribución – No comercial
http://purl.org/coar/access_right/c_abf2
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Fundación Universidad de América
publisher.none.fl_str_mv Fundación Universidad de América
institution Universidad de América
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1841553078439903232
spelling Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San ViatorLodos activadosReactor aerobioCrecimiento biológicoActivated sludgeAerobic reactorBiological growthTesis y disertaciones académicasIn the present work of degree, it is presented the implementation of a system of wastewater treatment, through the technology of activated sludge to the domestic wastewater generated in the institutional activities of the San Viator school for its later dumping in the wetland of Torca -Guaymaral, since the preliminary treatment that is currently carried out does not meet the requirements of environmental regulations. For the evaluation of this treatment, the project was divided into three phases, firstly, the diagnosis and characterization of the wastewater sources, finding that parameters such as total suspended solids, fats and oils, COD and BOD5 do not comply with the Provisions. Subsequently, the treatment alternative chosen by means of the construction, commissioning and operation of a conventional system of activated sludge on a laboratory scale is developed experimentally, allowing the determination of the biological growth kinetic coefficients used in the third phase of the project, which corresponds to the dimensioning Of the units involved in the treatment system. Finally, and based on quotations, the costs of the installation and proper operation of an activated sludge treatment train are estimated.En el presente trabajo de grado, se presenta plantea la implementación de un sistema de tratamiento de aguas residuales, mediante la tecnología de lodos activados a las aguas residuales domésticas generadas en las actividades institucionales del colegio San Viator para su posterior vertimiento en el humedal de Torca-Guaymaral, ya que el tratamiento preliminar que se lleva a cabo actualmente no cumple con las exigencias de las normativas ambientales. Para la evaluación de dicho tratamiento, se dividió el proyecto en tres fases, en primer lugar, realizó el diagnóstico y caracterización de las fuentes de agua residual, encontrando que parámetros como sólidos suspendidos totales, grasas y aceites, DQO y DBO5 no cumplen con las disposiciones legales. Posteriormente se desarrolla experimentalmente la alternativa de tratamiento escogida mediante la construcción, puesta en marcha y operación de un sistema convencional de lodos activados a escala de laboratorio, permitiendo determinar los coeficientes cinéticos de crecimiento biológico usados en la tercera fase del proyecto, que corresponde al dimensionamiento de las unidades involucradas en el sistema de tratamiento. Por último, y a partir de cotizaciones, se estiman los costos que implican la instalación y correcto funcionamiento de un tren de tratamiento por lodos activados.Colegio San ViatorFundación Universidad de AméricaOsorio, Gilberto AndrésRamos Velandia, Cristian Camilo2018-07-05T17:55:32Z2018-07-05T17:55:32Z2017-08-23bachelorThesishttp://purl.org/coar/resource_type/c_7a1fapplication/pdfAPA 6th - Ramos Velandia, C. C. (2017) Evaluación de un sistema de tratamiento de lodos activados para la remoción de carga orgánica en las aguas residuales domésticas generadas en el Colegio San Viator (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6578https://hdl.handle.net/20.500.11839/6578Atribución – No comercialYo (nosotros) en calidad de titular(es) de la obra, autorizo (autorizamos) al Sistema de Bibliotecas de la Fundación Universidad América para que incluya una copia, indexe y divulgue en el Repositorio Digital Institucional – Lumieres, la obra mencionada con el fin de facilitar los procesos de visibilidad e impacto de la misma, conforme a los derechos patrimoniales que me(nos) corresponde(n) y que incluyen: la reproducción, comunicación pública, distribución al público, transformación, en conformidad con la normatividad vigente sobre derechos de autor y derechos conexos (Ley 23 de 1982, Ley 44 de 1993, Decisión Andina 351 de 1993, entre otras). Al respecto como Autor(es) manifestamos conocer que: - La autorización es de carácter no exclusiva y limitada, esto implica que la licencia tiene una vigencia, que no es perpetua y que el autor puede publicar o difundir su obra en cualquier otro medio, así como llevar a cabo cualquier tipo de acción sobre el documento. - La autorización tendrá una vigencia de cinco años a partir del momento de la inclusión de la obra en el repositorio, prorrogable indefinidamente por el tiempo de duración de los derechos patrimoniales del autor y podrá darse por terminada una vez el autor lo manifieste por escrito a la institución, con la salvedad de que la obra es difundida globalmente y cosechada por diferentes buscadores y/o repositorios en Internet, lo que no garantiza que la obra pueda ser retirada de manera inmediata de otros sistemas de información en los que se haya indexado, diferentes al Repositorio Digital Institucional – Lumieres de la Fundación Universidad América. - La autorización de publicación comprende el formato original de la obra y todos los demás que se requiera, para su publicación en el repositorio. Igualmente, la autorización permite a la institución el cambio de soporte de la obra con fines de preservación (impreso, electrónico, digital, Internet, intranet, o cualquier otro formato conocido o por conocer). - La autorización es gratuita y se renuncia a recibir cualquier remuneración por los usos de la obra, de acuerdo con la licencia establecida en esta autorización. - Al firmar esta autorización, se manifiesta que la obra es original y no existe en ella ninguna violación a los derechos de autor de terceros. En caso de que el trabajo haya sido financiado por terceros, el o los autores asumen la responsabilidad del cumplimiento de los acuerdos establecidos sobre los derechos patrimoniales de la obra. - Frente a cualquier reclamación por terceros, el o los autores serán los responsables. En ningún caso la responsabilidad será asumida por la Fundación Universidad de América. - Con la autorización, la Universidad puede difundir la obra en índices, buscadores y otros sistemas de información que favorezcan su visibilidad.http://purl.org/coar/access_right/c_abf2spaoai:repository.uamerica.edu.co:20.500.11839/65782025-02-01T08:15:59Z