Análisis de una celda de pervaporación para el sistema IPA-agua
The pervaporation cell is considered as the module where the mass transfer phenomena occur from the retentate in liquid phase to the permeate in vapor phase. This document allows to observe the behavior of the material transfer for the binary mixture isopropyl alcohol-water. The material flux of eac...
- Autores:
- Tipo de recurso:
- Fecha de publicación:
- 2016
- Institución:
- Universidad de América
- Repositorio:
- Lumieres
- Idioma:
- spa
- OAI Identifier:
- oai:repository.uamerica.edu.co:20.500.11839/6437
- Acceso en línea:
- https://hdl.handle.net/20.500.11839/6437
- Palabra clave:
- Celda de pervaporación
Permeato
Permeabilidad
Retentato
Pervaporation cell
Permeability
Permeate
Retentate
- Rights
- License
- Atribución – No comercial
| Summary: | The pervaporation cell is considered as the module where the mass transfer phenomena occur from the retentate in liquid phase to the permeate in vapor phase. This document allows to observe the behavior of the material transfer for the binary mixture isopropyl alcohol-water. The material flux of each component was calculated to make a comparison between them, in order to analyze the selectivity with the silica membrane. Finally, the molar flux obtained for the water was 0.0248 kmol/m2 h for a mixture with 15 % of water, which allows to establish that the inorganic membrane is selective to water. |
|---|