Análisis de una celda de pervaporación para el sistema IPA-agua

The pervaporation cell is considered as the module where the mass transfer phenomena occur from the retentate in liquid phase to the permeate in vapor phase. This document allows to observe the behavior of the material transfer for the binary mixture isopropyl alcohol-water. The material flux of eac...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2016
Institución:
Universidad de América
Repositorio:
Lumieres
Idioma:
spa
OAI Identifier:
oai:repository.uamerica.edu.co:20.500.11839/6437
Acceso en línea:
https://hdl.handle.net/20.500.11839/6437
Palabra clave:
Celda de pervaporación
Permeato
Permeabilidad
Retentato
Pervaporation cell
Permeability
Permeate
Retentate
Rights
License
Atribución – No comercial
Description
Summary:The pervaporation cell is considered as the module where the mass transfer phenomena occur from the retentate in liquid phase to the permeate in vapor phase. This document allows to observe the behavior of the material transfer for the binary mixture isopropyl alcohol-water. The material flux of each component was calculated to make a comparison between them, in order to analyze the selectivity with the silica membrane. Finally, the molar flux obtained for the water was 0.0248 kmol/m2 h for a mixture with 15 % of water, which allows to establish that the inorganic membrane is selective to water.